AccessPort监控的数据 解析解决方法

AccessPort监控的数据 解析
# Time Function Data ( Hex )

1 [00000000] IRP_MJ_CREATE Port Opened - T
2 [00000000] IOCTL_SERIAL_SET_BAUD_RATE Baud Rate: 9600
3 [00000000] IOCTL_SERIAL_SET_LINE_CONTROL StopBits: 2, Parity: No, DataBits: 7
4 [00000001] IRP_MJ_WRITE Length: 0021, Data: 05 30 30 46 46 51 52 30 52 30 30 35 30 35 31 30 31 39 44 0D 0A 
5 [00000006] IRP_MJ_READ Length: 0008, Data: 02 30 30 46 46 30 30 30 
6 [00000006] IRP_MJ_READ Length: 0006, Data: 30 03 41 46 0D 0A 
7 [00000008] IRP_MJ_WRITE Length: 0021, Data: 05 30 30 46 46 51 52 30 52 30 30 35 30 35 31 30 31 39 44 0D 0A 
8 [00000012] IRP_MJ_READ Length: 0008, Data: 02 30 30 46 46 30 30 30 
9 [00000013] IRP_MJ_READ Length: 0006, Data: 30 03 41 46 0D 0A 
10 [00000014] IRP_MJ_WRITE Length: 0021, Data: 05 30 30 46 46 51 52 30 52 30 30 35 30 35 31 30 31 39 44 0D 0A 
11 [00000019] IRP_MJ_READ Length: 0008, Data: 02 30 30 46 46 30 30 30 
12 [00000019] IRP_MJ_READ Length: 0006, Data: 30 03 41 46 0D 0A 
以上是用AccessPort软件监控某个窜口软件获取的数据。我转换成ascII 码感觉不大对劲。
求人帮忙分析一下,这些16进制说了些什么信息,是否可能为加密的。

------解决方案--------------------
一般来说,02 03之间的表示数据域
于是猜想:
30 30 46 46 30 30 30 30
是表示一定意义的数据⋯⋯
具体请看ASTM1394协议
------解决方案--------------------
规律性不是那么强,不好分析。最好是搞来通信协议。